Recordar é preciso: Fração de ejeção (Convidados)
Cuidados a ter:
– certificar-se que a via apical está bem “apanhada” (VE em forma de cone com visualização das valvulas mitral e tricúspide e aurículas)
– conseguir a melhor definição possível do endocárdio
– a medição do volume sistólico e do volume diastólico devem ser calculados no mesmo ciclo cardíaco.
.
Enviado por Ana Feijão
.
Fonte: https://www.stanford.edu/group/ccm_echocardio/cgi-bin/mediawiki/index.php/Left_ventricle_systolic_function
.
Hemorragia intraplaca: Diferente e pior.
Sustained Acceleration in Carotid Atherosclerotic Plaque Progression With Intraplaque Hemorrhage
E quem se importa com a exatidão?
Assessment of Echocardiographic Left Atrial SizeHow Accurate Do We Need to Be?.LINK.Finally, it is pertinent to ask how much certainty is needed to conclude that the left atrium is enlarged, particularly when existing cut points are known to have predictive accuracy. Mor-Avi et al. (9) convincingly demonstrated that RT3DE more accurately measures LA volume than biplane 2DE. However, it is unclear whether the incremental benefit of RT3DE for LA volume measurement is valuable clinically. Stated another way, just how accurate do we need to be to be certain?.Sempre que o 3D acerta uma, um experiente colega desfaz o milagre..Só na ecocardiografia!.Na RM e Tomo, qualquer mudança de resolução de 0,001 mm é festejada como a cura das neoplasias!!!!.Só quando nascerem os ecocardiografistas 3D em tempo integral, essa ducha de água fria dos velhos ecocardiografistas secará..
Abaixo os diâmetros e áreas, agora é volume real.
Real-Time 3D Echocardiographic Quantification of Left Atrial VolumeMulticenter Study for Validation.LINK.
Results 3DE-derived LAV values showed higher correlation with CMR than 2DE measurements (r = 0.93 vs. r = 0.74 for maximal LAV; r = 0.88 vs. r = 0.82 for minimal LAV). Although 2DE underestimated maximal LAV by 31 ± 25 ml and minimal LAV by 16 ± 32 ml, 3DE resulted in a minimal bias of −1 ± 14 ml for maximal LAV and 0 ± 21 ml for minimal LAV. Interobserver and intraobserver variability of 2DE and 3DE measurements of maximal LAV were similar (7% to 12%) and approximately 2 times higher than CMR (4% to 5%). 3DE classified enlarged atria more accurately than 2DE (kappa: 0.88 vs. 0.71).
Conclusions Compared with CMR reference, 3DE-derived LAV measurements are more accurate than 2DE-based analysis, resulting in fewer patients with undetected atrial enlargement.
Vivid "e", "i" ou "q".
.
No congresso, um simpático representante da marca me explicou finalmente as diferenças.
.
Caso eu tenha entendido, é assim:
.
O Vivid “e” segue o padrão do Vivid 3.
O Vivid “i” segue o padrão do Vivid 5.
E o Vivid “q” segue o padrão do Vivid 6, com a vantagem significativa de aceitar o transdutor (muito bom) matricial.
.
.
Agora sim, a Esaote é portátil e moderna.
.
Fãs da Esaote, preparem seus bolsos.
Já regulamentado no Brasil, o verdadeiro portátil da marca italiana.
.
Testei o aparelho e é muito bom.
Tela de matriz ativa e com rotação ampla.
Taxa de quadros alta mesmo com o ColorDoppler ligado.
Transdutor com boa definição e leveza.
.
Peso e qualidade para uso em qualquer região do país.
.