10 anos de EchoPAC


.
Em 2000, comecei a trabalhar na unidade do Delboni, agora Diagnóstico das Américas, na avenida Brasil.
Do nada, surgiu um aparelho magnífico, o System Five.
Fui incumbido na tarefa de domar a fera, com a ajuda da Carla, que era técnica de aplicação na época.
O aparelho era fantástico, anos-luz a frente dos concorrente, produzido pela Vingmed, que fazia parte da GE.
.
Já estava me achando o ecocardiografista mais sortudo do mundo, só com o uso básico do aparelho.
Aí a Carla me apresentou o EchoPAC.
Um software de análise de imagens que funcionava à parte em um computador Apple que ficava no console do aparelho.
Em 2000!
Analisava os clips de imagens com “raw data”. Fazia ecostress, dava zoom, coloria, tissue Dopppler, power gain e veja vocês, reconstrução do volume ventricular em 3D!!!
Ánalise vetorial da contratilidade vinha de bônus…
.
Parecia um software criado por malucos por imagem, particularmente ecocardiografia, financiados por algum Steve Jobs da medicina.
.
Hoje não trabalho mais no Delboni, virei professor, a Carla é chefe, e o EchoPAC continua por aí.
.
Mas tenho saudade daquelas semanas de descoberta, fuçando uma máquina que dava muito mais do que eu era capaz de entender…
.

Site Cardiosource em português agora com editor para imagens


.
O melhor site em português de cardiologia agora têm um editor especializado para métodos de imagem.
Assim, nosso ecocardiograma e Doppler de carótidas terá espaço no site científico mais acessado em língua portuguesa.
.

A página mais dinâmica do Brasil !!!


.
Quero parabenizar o D.I.C e sua atual diretoria por mais esse feito.
17 dias após a prova mais cruel dos últimos 10 anos e nenhuma informação oficial.
Silêncio total em resposta à revolta dos avaliados.
.
Esse é o DEPECO de sempre, com novo nome e pensamentos congelados.
.
Ser presidente do DEPECO foi mesmo, até hoje, algo como o título de “Sir”.
(Historicamente, o título de “Sir” indicava a superioridade de alguém em relação aos escravos dos quais era amo ou aos vassalos aos quais dominava em troca de protecção.)
.
Nossa ex-presidente estava certa!!!
.

Embolia gasosa ao ecocardio


.
The incidence and haemodynamic significance of gas emboli during operative hysteroscopy: a prospective echocardiographic study
.
Acompanho algumas cirurgias para obesidade por via laparoscópica. Sempre me pergunto para onde vai aquele gás injetado no peritônio.
Ainda não descobri.
Mas o estudo acima respondeu essa pergunta no caso da histeroscopia.
Vai para o ventrículo direito!
.
Um belo exemplo de como usar o ecocardiograma para responder questões médicas relevantes, uma prova concreta do uso cada vez mais amplo da ecocardiografia.
.

Cada máquina faz um strain diferente?


.
The clinical implications of these discrepancies are significant. Although ‘global longitudinal’ strain appears to be comparable, at the current stage of development, ‘global radial/circumferential’ and ‘regional’ strain calculations should not be considered to be transportable between vendors. Therefore, if strain is being used in longitudinal follow-up, baseline and follow-up images need to be obtained using the same system.
.
Editorial de Thomas H. Marwick
European Journal of EchocardiographyVolume 11, Issue 5Pp. 414-416
Comentando sobre o artigo abaixo:
.
Assessment of left ventricular function by different speckle-tracking software
.
A avaliação da deformação por softwares diferentes, leva a resultados nem sempre comparáveis.
Qual análise vai prevalecer?
Essa é a pergunta a ser respondida antes de se comprar um aparelho com Strain.
.

A fina linha que divide a teimosia da falta de bom senso…


Stress echocardiography in the district hospital setting: a cost-saving analysis
Nicolai Wennike1, Benoy Nalin Shah2, Emma Boger2, Roxy Senior3 and Kim Greaves
.
European Journal of Echocardiography. Volume 11, Issue 5Pp. 401-405.
.
The cost saving of stress echocardiography, an accuracy analysis, and adverse outcomes at 6 and 24 months follow-up were determined. The total cost attributable to the stress echocardiography service was £58 368. If unavailable, 78 (39%) patients would have been referred for angiography and 122 (61%) for perfusion scintigraphy at a cost of £56 316 and £42 090, respectively, with a total cost of £98 406. This represents a cost saving of £40 038.

Conclusion Stress echocardiography is a cost saving method for the investigation of chest pain in patients with low–intermediate risk of flow limiting coronary artery disease in the district hospital setting.
.
In the case of exercise stress echocardiography, BRUCE protocol symptom-limited treadmill exercise testing was performed with images acquired immediately (within 90 s) after peak exercise. Early post-exercise images with the best endocardial definition were displayed alongside the corresponding baseline images. In patients in whom exercise testing was deemed not possible, dobutamine was infused peripherally in 3 min dose increments, starting from 10 µg/kg/min and increased to 20, 30, and 40 µg/kg/min.
.
Estudo mostra que o Ecostress é uma ferramenta eficiente e viável, na análise da dor torácica.
Sempre que possível, com o esforço.
.
É barato, rápido e seguro. Mas isso não basta para convencer certos serviços de cardiologia que insistem no ecostress farmacológico ou na cintilografia…
.

3D para fazer 2D…


Pitfalls of anatomical aortic valve area measurements using two-dimensional transoesophageal echocardiography and the potential of three-dimensional transoesophageal echocardiography
.
European Journal of EchocardiographyVolume 11, Issue 4Pp. 369-376
.
Conclusions

Two-dimensional speckle tracking analysis revealed movements of aortic annulus along its long-axis direction as well as tilting movement during the cardiac cycle. These dynamic movements might be the main cause of misalignment of the true cross-sectional view, resulting in the inaccurate calculation of anatomical AVA using 2DTEE. Volumetric 3DTEE data sets encompass the entire AV, and thus, allow the delineation of the tangential 2D cut plane at the tip of the AV cusps. Two-dimensional planimetric calculation of AVA from volumetric 3DTEE data sets is a new useful technique for measuring anatomical AVA in patients with AS.
.
Although both methods showed moderate correlation with AVA by CE (r = 0.78, 0.75), mean differences were significantly smaller by 3DTEE than 2DTEE (−0.01 ± 0.25 vs. −0.17 ± 0.27 cm2, P < 0.001).
.
Pesquisa acima afirma, baseado em diferenças estatísticas mínimas, que o 3D transesofágico mede melhor a área aórtica , mas usando a análise 2D!!!
.
É curioso observar a “desconstrução” do 3D para um 2D que o médico consiga entender.
Acontece na tomografia de coronária, por exemplo.
Apesar de obterem uma foto 3D, essa serve apenas para a torcida, já que a análise é sempre no 2D…
.
No congresso, várias fábricas de máquinas de eco alardeavam que seus 3D produziam múltiplas imagens 2D!!!
.
Depois se queixam das vendas ocasionais. Quem quer comprar uma Ferrari, a preço de Ferrari, para andar a 80km/h?
.

D.I.C. : Nome aos bois e o envolvimento.


.
COMISSÃO DE HABILITAÇÃO
Coordenador Dr. David Costa de Souza Le Bihan – SP
.
Após a prova, muitas manifestações de repúdio ao método usado na avaliação.
.
A exaltação serve, como vimos em alguns comentários, para gerar uma reação ordenada e funcional.
.
Primeiro, a prova foi feita pela diretoria acima, com seu presidente sendo o principal responsável.
A chapa de 2012, vencedora das eleições, não pode ser responsabilizada.
.
Segundo, esperar a divulgação dos resultados é o correto, antes de providências como boicote ao D.I.C. ou medidas legais.
.
Terceiro, envolver-se com o departamento só quando seus interesses são atacados, não vai fazer do D.I.C uma sociedade eficiente e justa.
.
O homem é um animal político, como disse Aristóteles, e deve usar a política para cuidar dos interesses da sociedade, em tempo integral.
.